Multimeter (Multimeter). Multimeters is considered the necessary measurement tools for electronics, because that is a basic measure used is the electrical voltage, electric current and electric resistance, whether test or make repairs to various circuit, it's necessary to measure the total of those values. Voltmeter Ammeter and a multimeter Ohmmeter in the same and the use of a single movement (the Movement) is called "VOM" (Volt-Ohm-Milliammeter).The hierarchy using a DC voltmeter 1. DC voltage measurements while volts across the load. 2. set the meter's running neighborhood district in DCV. 3. set the switch to the correct measure If you don't know the voltage measurement, set the maximum measurement position (1, 000V) first and then the downgrade to a lower district and districts until the meter needle will point values that are readable and accurate. 4. position the gauge with a DC voltmeter, measure, while not touching the wires but more positive or positive, while pulling the measure comes out. The meter needle will always point to slightly wiggle the temple shows that it is AC voltage (ACV). 5. measurement of voltage in the circuit will need to plug the correct measurement by measuring the negative line (a-COM), black handle negative supply. Bring the wire gauge positive (+) Red clamp meter to measure the voltage. Sequence the steps to use a ohm meter. 1. set the meter's running neighborhood district ohms. 2. use the red measuring cable plug into the connector on the positive. (+) And the black measuring line into the plug connector negative pole (a-COM). 3. adjust the switch router CD, small neighborhood Temple, is correct. 4. prior to the introduction of an ohm meter to measure every time and in every district will have to adjust the 0 ohm always. 5. If the ohm meter to measure, will lead the resistance in the circuit, be sure the power switch is turned off (OFF) all the time. Caution in use of the multimeter. 1. do not expose the thermometer is affected, such as sudden drops from higher will cause measurement instrument defective. Damaged. 2. place the thermometer in position should be flat (horizontal) while active and retired. 3. before measuring, make sure every 12th puzzling selection measure. 4. set the maximum scale of the measure while measuring points that do not know the exact value. 5. do not use the measurement in ohms measurement voltage direct voltage or alternating. 6. when measuring voltage must use direct measurements, is +-always. 7. when the select measurement in ohms should not give end-of-line measure, tap each other for too long. 8. When should unplug the gauge out and select switch OFF to the district. 9. should not Overload occur (scale) the multimeter. Frequently, time of measurement must show the location of measurement, measure them properly. With the circuit to be measured. 10. the multimeter is not used for a long time before you use the Function and Range switch should be rotated to reduce stiffness and, Good electrical contact 11. thermometer should be stored, wrapped in the (Case).
การแปล กรุณารอสักครู่..
