Design and building improvementTo design and improve the building of walls.Before the value adjustment total heat transfer of wall on the outside of the building (OTTV) has nine-thirty seven point estimates nine Watts per square meter. It has taken out the discount glass wall area.By modifying a solid ten millimetre thick fiber cement walls. With fiberglass insulation in the middle that has a low thermal conductivity. About 0.038 3 inches thickness W2m.KThe glass wall and did not adjust to a solid wall to install film thermal properties on thermal protection by using film that is SC = 0.23 and SHGC values = 0.201 resulted after the OTTV values updated design of the building only 18.95 Watts per square meter, corresponds to the actual scope of the project, research determined that the OTTV must not exceed 20 Watts per square meter.