Article 14 the building for use as a hotel, according to the article 10 must have the aisle inside the building width not less than 1.50 m.Article 15 the building for use as a hotel, according to the article 10 must have a fire escape or escape a fire according to the criteria and conditions set out in the legislation to control the building.Article 16 the building for use as a hotel by the combination of space and 10 floors in the same building more than 2, 0. Square meters. Inside the building must be provided with emergency backup power for such a battery or generator separated from the system that is in use, and can run automatically when the normal power supply stopped working.Power system back up in accordance with paragraph 1 shall. Must be able to supply sufficient power for the emergency exit. Walkway. Fire escape stair Hall and the fire alarm system for a period of not less than two hours.Article 17 wells and ponds to filter your toilet's septic tank, building for use as a hotel, according to the article 10 must stay away from the river canals, or public water source not less than 10 metres, except for cases where there are toilet sewage disposal system, based on the principles of sanitation and proper size.