1.1. the following control system 1.1.1. the water control system. Control of water, the chicken is a standard value to the source of water is the water from wells deep underground that is filtered and then stored in the tank size to 5000 ml water to open the valve to the water delivery tube onto the machine according to the filter, and then kept the ball through a water tank, and then send the new hose into a cup that can be adjustable "pitch to suit each age range chickens.1.1.2. the food control system.To chant from the plant's quality control CP network will be transported by truck to transport the food from the scene and disinfected before leaving the factory, feed forward onto the farm entrance is through sterilization by liquid solutions (iodine) and highlighting how to mix liquid net volume 1:200 litres in farm to send food stored in a silo with a food dryer method and the sensor, pull the food into the work order greenhouses online using Rails with protection and prevention because akoe insects from outside the services catch on top before monsen greenhouses and pulling to the food box.At the top of the box to store your food will have a little sensors get food from the food into the food boxes, silos when it comes to food, food will be sent according to the feed Rails with chains and chain-driven gear-Sen is to be prosperous to be diffused and direct 1 curve 4 for food flows through finally rang, food can be defined around the height of the food from the food at alongside the valve open.1.1.3. the temperature control system.Source, reducing the temperature in the greenhouses will use the system Cooling Pad with an element, as follows: Exchange cellulose paper Pad from the outside inward support plate Substrate water water which serves the flow back to the Pad again below the plate Rails to accommodate the water capacity 48 l. Water pump water pump draws water up to release the Pad into the heat exchanger. float valve float valve controls the water in the tank when the water tank is full, then backed up.Cooling Pad by the time has been set, the water from the pump to the air Pad, fan pulls out all 16 are the opposite of Pad to keep the air from outside through a passive heat from the Pad becomes cold, depending on the Pad in front of the open window in the size 104m x 12m x housing 3.8 m with 3 Pad is venting all 78 channels, top with small blower 6 to prevent the emergency heat when a power failure occurs.1.1.4 the lighting control system.Can be set from time to time to suit the age of the chicken, because the light is very influential on growth and the creation of hormones will also affect the length of time the eggs very light chicken, if the hormone is not complete, it will rapidly for a period shorter than usual, eggs?The system can be verified with the Viper with the elements of the system as follows:1. check the water to eat.2. check the quantity of chicken to eat.3. check and reset the temperature and humidity values.4. define the light inside greenhouses
การแปล กรุณารอสักครู่..