The parts of the microscope-microscope components
Bright Field
1. base (BASE) serves the entire weight of the microscope. There is a rectangular shape or circle at the base, there will be a button to turn off power open
2. Arm (ARM) as well as on ships and bases. Use a timer to move microscope
3. Boat camera (BODY TUBE) is next to a hollow tube with handle end of the top has a lens near the eye wear is on the other side there are a combination of lens, near the object that is stuck to the dish twist called Revolving Nosepiece
4. The object pallet (STAGE) as a platform for putting slide examples to study. There is a rectangular platform. Also called Mechanical Stage Moreover, the scale of objects placed on the slide instead. You can tell the position of the picture on the slide,
.5. optical lenses as well (CONDENSER) side of the lens as the object pallet light to light to an object on a slide. Can move up down buttons are
6. Iris diaphragms (DIAPHARM IRIS) is a closed curtain open aperture. Unable to adjust the size of the aperture. A lever for adjusting the size of the aperture is below under the pallet object
7. Object lens (OBJECTIVE LENS) will be stuck with a rotating plate. Which is part of the camera contains a lens, which is the light that shines through from the objects that bring education (Specimen) to beam through the lens closer to the object. And make a picture that has a real head back
. (Real Primary Image) by the lens near the object has a different extension is:
- The lens near the object is less (Lower Power) 4X
10X, expanding-lens near the object being extended height (High Power) 40X
-Oil Immersion lens near the object size 100X
8. REVOLVING NOSEPIECE is part of the camera that was used for the rotation. To change the expanding of the lens near the object
9. The lens near the eye (OCULAR LENS or EYEPIECE LENS), this lens will wear the trunks, there are cameras numeric display is on top, such as 5X, 10X or 15X, etc. The camera is used in General Microbiology Laboratory. With the eye of the lens is 10X models with single-lens eyes closer to the lens. Call the Monocular Microscope, there are two types of eye lens lens close. Called Binocular Microscope
10. Rough image buttons (COARSE ADJUSMENT KNOB) used to move the position of the object pallet. In the distance, it will visualize. This is a large button on the side of the camera
11. Phaplaiat buttons (FINE ADJUSMENT KNOB) is a small button next to the rough image buttons come out outside in the same location or some types of camera may be nearby.