Rules of the Ministry ofVol. 2 (2535 (1992))Released on the factory Act2535 (1992) [1] Live, on-demand power in section 6 and section 8 (1) (2) (3) (4) (5) (6) and (8) of the Act 2535 (1992) factory, the Minister of industry, to rule out the Ministry. In the following ways: Chapter 1Environmental area Building styles and features inside of the factory. Article 1 prohibits such factory at 1 and 2 at such factories in the area. In the following ways:(1) housing estate to housing Condominium and residential homes for the row.(2) within 50 m from the county public school or contact education institutions including around temples or places of worship, the hospital. And the place of work of the State authorities, and this means including laengonurak natural resources and the environment, according to the Council of Ministers. Article 2 do not set up factories such as the 3 in the following area.(1) housing estate to housing Condominium and residential homes for the row.(2) within 100 m from public school or contact education institutions including around temples or places of worship, the hospital. And the place of work of the State authorities, and this means including laengonurak natural resources and the environment, according to the Council of Ministers. Article 3 the place of work of the State authorities in accordance with article 1 (2) or article 2 (2) does not necessarily mean, as well as the place of work, in particular to further regulatory control of facilities or service operations of the factory.If you have a valid reason. The Minister is determined by publication in the Government Gazette, to retract or extend distances set out in article 1 (2) or article 2 (2), or to use force any 1 (2) as well as what type of plant according to the criteria that define it. Article 4 3 a medical factory in addition to prohibited in the area, according to the article 2, must be located and appropriate environment. There is enough area to business industry by size and type, or the type of plant. Without can cause hazard or cause damage to the person or property of others. Article 5 building the factory must have the following characteristics:(1) stable, strong and fit enough to make the industry parties with a certificate of professional engineering controls or other persons that the Minister is determined by publication in the Government Gazette.(2) there is an appropriate ventilation with door area. Windows and vents together without thousands of contacts between the city of not less than 1 in 10 parts of the area of the room or ventilation of not less than 0.5 cubic meters per minute. One work per person.(3) a door or exit, the number of people satisfied with the factory to escape danger from Nick when the emergency occurred, at least two are sufficiently. Easy-to-open door width of not less than 110 cm and height of not less than 200 centimeters, but if someone in the factory will be based on the more than 50 people there must be a large increase in the ratio of not less than 2 cm per person and includes stairs between two or more layer is sufficiently.(4) there must be a strong stable ladder style, size, and number of suitable factory building and industrial entrepreneurship. There must not be slippery and stepped over the same period by all.Stair and walkway at ground level from the ground of at least 1.50 m or more stable racks must be strong and suitable for both. The Minister may determine by publication in the Government Gazette, with other components in order to prevent danger or, except as provided above.(5) the distance between floor and ceiling to plummet by an average must not be less than 3.00 m, unless there is air conditioning or ventilation fitting. But the placing period must not be less than 2.30 meters.(6) the surface must be stable, strong. There are no water or fluid may cause accidents.(7) areas or Office must have operational area of not less than 3 square metres. One work per person by calculating the area, including areas that are placed in the task table. Machinery. Product, or material that moves along the route.(8) an object that is used in construction must be suitable for industrial enterprises by size, assembling a category or type of plant, including those that did not cause the fire to spread of.(9) provide a cable lure sky as necessary and appropriate.(10) provide that maintains an object or thing that can cause hazard or fire it in a safe place easily.(11) in the event there is an elevator. Elevator safety components must be no less than four times the weight assigned to use this by holding that people carry weight 70 kg per person and must be to move only when the door is closed, as well as the need to have the system send a signal when the emergency occurred. The elevator must have labels indicating how many people or weight to carry. Provide a clear and easy to see.(12) there is a toilet and urinal cleaner body. In the following ways:(A) there is at least a toilet at a rate of no more than 15 workers who 1 seats. Workers do not exceed 40 people, 2 seats. Workers cannot exceed 80 people, 3 seats and the rise in the ratio of 1 seat per person for no more than 50 people work for the factory workers are male and female workers as well as more than 15 people, though held for female workers, according to the ratio defined above.(B) the factory building with people running multiple layers. Must be provided with toilet and urinal in layers as necessary and appropriate.(C) toilet must have an area of not less than 0.9 m2 per 1 seat.(D) the toilet had urine must be used to pay down the absorption of water wells. Flooring must be not suck water.(E) to provide toilet paper or water for a sufficient toilet in every room.(F) provide a cleaning around the body, along with supplies and equipment for workers, as necessary and appropriate.(H) Provide adequate ventilation to vent for a toilet Laboratory urine and cleansing the body in every room(Gonzalez) Provide a clean toilet and urinal cleaner around the body in a condition that is hygienic conditions daily.(Chaw-Ka-Cher) In the factory that is producing something that is consumed. Must be provided with wash basin? Disinfectant or SOAP which have hygienic conditions and is located in the.
การแปล กรุณารอสักครู่..