4.1 can be moved to a different surgery. The explosion spread radiation and is less.4.2 with curved arm C based.Abstain with x-ray Xray images that convey chutklong at the end of each side of the arch sleeve picture set C.4.3 system review (Fluoroscopy) to illuminate the image signal, the image can be displayed immediately after x-ray.Touch screen monitor 4.4 Have placed on the same wheel base and be able to move.4.5 Digital Image Storage that can Have images in your Hard Disk has more than 8000 images and other Removable Data storage can be stored, such as a USB Port, and CD/DVD-RAM drive.PACS System can accommodate more than 4.6.Size 220 volt electricity use, 4.7/50 Hz.Technical khonsombat5.1 Xray generator5.1.1 High Frequency5.1.2 Fluoroscopy kV 40 Kvp range up to 75 Kvp.5.1.3 Have tube current 0.02 mA to 0.10 mA5.2 Xray tube and Fluoroscopy Mode5.2.1 Anode tungsten type.5.2.2 Use focus point 0.05 mm or less than 0.05 mm.5.2.3 can adjust highest power value 75 kVp5.2.4 can be adjusted to the maximum flow at 75 kVp 0.10 mA.5.2.5 Have auto dose control5.2.6 Can choose to use X-ray Control mode, it must be can use Auto IQ mode, Auto mode and Manual mode5.2.7 Have Snap shot(single shot), Continuous (Fluoroscopy) and Digital Recordes Fluro (Cine)5.2.8 Have radiation report5.3 Iamge Receptor/Detector5.3.1 Image Receptor is flat detector type.5.3.2 Pixel more than 75 micron5.3.3 Can choose mode image receptor 2 type or more than following message 5.3.3.1 Full field mode image size 5.5x4.5 " or more than.5.3.3.2 Limited Field mode image size 4.4" or more than5.3.4 Detector Rotation +/-90 degree5.3.5 adjusting the beam of a collimator is a type of Auto Tracking Collimation.5.4 C-arm working systems5.4.1 Free space of C-arm 36 cm. or more than.5.4.2 Depth of C-arm 50 cm. or more than5.4.3 Highest Pivot Rotation 120 degree or more than.5.4.5 Can adjust vertical highest 58 cm. or more than.5.4.6 Can adjust Panning Motion type highest 320 degree or more than.5.5 Touch screen monitor 5.5.1 Touch screen monitor is Flat Panel monitor type and size 20" or more than.5.5.2 Screen detail pixel 1600x1200 or more than.5.5.3 Can rotate screen monitor position 350 degree or more than5.5.4 the maximum rate or the image in more than 30 pictures per second for slides and animations can be saved (Cine) is a maximum of 25 images per second or more.5.5.5 Have image Processing size 16 bit or more than.5.6 Image Processing5.6.1 Have Automated Image Processing systems.5.6.2 Have Automated REal time noise reduction systems.5.6.3 Have Edge Enhancement systems.5.6.4 Have Auto-Dose Control.5.6.5 Can adjust magnify,Zoom and Pan image.5.6.6 Can adjust Brightness and Contrast5.6.7 Use Windows XP or new than window XP and have antivirus for convenience to use and manage data.5.6.8 Support DICOM systems5.6.8.1 Modality Worklist5.6.8.2 Print5.6.8.3 Store5.6.8.4 Storage Commitment5.6.9 Computer systems that use to build medical image
การแปล กรุณารอสักครู่..