4. fire alarm
High-rise buildings must have fire alarms on every floor. Detector 2 is a device consisting of a smoke detector or heat disorders and Alarm, which is a signal in the form of light or ringing
a hand-held fire extinguishers 5.
Install fire extinguishers on every floor of the building to. The initial fire control and fire suppression system shall provide automatic Sprinkle System
6. Keep water system back up and lightning rod
system backup water storage facilities can help to fire the firemen have. The lightning rod to help prevent damage from lightning
7. stairs in high-rise
buildings everywhere must have a fire escape from the top floor down to the ground by at least two of which must be in a position to have. easily and without obstructions The key will be not as inconvenient as a spiral staircase running down. For the three-storey building with a basement or up to seven meters deeper than required to have a fire escape to the ground. In case of fire, do not use the stairs and escalator inside the building. Because these steps can prevent smoke and flame. Do not use the elevator because the elevator will stop any work
8. Suitable materials for walls, stairs
, walls and doors of the stairs inside the building must be made of fireproof material. It is a material that does not cause smoke as fire-resistant walls of concrete or masonry. To block the flame or smoke into the stairway
9. control smoke in the staircase
in the staircase will be a window to vent smoke or compressed air to increase pressure on the stairway. higher than the outside to prevent smoke from entering the ladder channel
10. The nature of fire doors
, fire escapes in the building will be provided with fireproof walls surrounding. In particular, the doors can be made of fire-resistant materials must also be the driving style to the interior of the fire escape. To facilitate the flow of people leaving the building. Unless a solution is on the ground floor or deck. Must be kind of pushed out to escape from the building quickly and easily. All doors should be equipped force the door closed automatically. To prevent smoke and fire into
the top 11. signs and fire exit signs
Stairwells inside the building will be provided with emergency lighting systems. The signs and floor fire escape signs that can be seen clearly. Both the inside and outside of each floor fire escape. To prevent the escape against a particular class in a tall building with a basement. Tags will help the fire that is now on the ground floor. And the exit to the outside
on the deck 12. The building
can be used as a fire escape on the fire escape of the building. By providing an open space and a 10x10 meter wide if we learn how to act in and fire prevention in buildings already. Dangerous, it will not happen to us.