The project the project is a building type CODOMINIUM SEAMAX live (condominium) over 19 floors, construction has taken its current division by building structures during construction projects that may affect the project surrounding residents both in the dust or noise, etc. However, the project has measures to prevent and correct the impact throughout the duration of the construction project. As follows:1) timing of construction activities that cause loud 08.00-17.00 hrs only. To prevent noise on neighboring communities. A case is made after 17.00 p.m. must be an activity that does not transmit noise surrounding residents provided to compensate for the damage to neighboring residential buildings. If the damage caused by the construction of the project. The project will be carried out to correct and provide assistance immediately.2) using solid canvas around a building project by adhere to the outer scaffolding from the ground floor to the top floor of the building while construction and must be maintained in good condition throughout construction to protect against dust explosion and to disseminate noise nearby.Sheet Metal fence installation 3) height of not less than 3 m surround block across the land, public land, and the different owners during the construction along and must be maintained in good condition throughout construction, in order to prevent the material fall from the construction curb to be diffused distribution of dust and construction zone signs prohibiting a person who is not related to the internal construction area.4 administrative engineers supply construction) closely and control of construction engineering requires in order to affect the area of the smallest side, including monitoring the impact of the construction of the residential building structure of persons once a month throughout the duration of the construction project.5) provides legal liability insurance life Body and property of the third party by showing a copy of the insurance policy schedule in construction area.6) while building a structure to Link Chain filed from the fallen buildings and materials to move every 2-3 layers.7) partitioned racks installation and optional mesh Part of the building construction with open channels, or there are no stalls to prevent the fall of construction materials.8) held a temporary chimney for dropping off construction materials in order to prevent dust or waste material from the debris left behind construction.9) install the box comments on Fort guards with a staffing complaint received from a vibration that may occur from the project to receive a complaint that may arise and examines guidelines for urgent corrections.10) establishes the statutory liability insurance life Body and property of the third party by showing a copy of the insurance policy schedule in construction area.Vibration measuring 11) once a month and report the results every month. Throughout the construction phase.12) provided to compensate for the damage to neighboring residential buildings. If such damage is caused by vibration from the construction project. Resolve and assist immediately.
การแปล กรุณารอสักครู่..