To get a license as a professional mechanical engineering, control engineering, ordinary-level healthcare engineers engineering mechanical engineering job type and size only:(1) planning and projects of all sizes(2) design and calculation.(A) mechanical size of not more than 750 kW per combination machine.(B) steam or steam generator. Pressure vessel or an industrial-sized furnace pressure does not exceed 4, 0 k Pascal or pressure vessel volume no more than 10 cubic meters per tank or steam production rate or something else not to exceed 20, 0 kg per hour.(C) complications, air dryer or a refrigeration cooling does not exceed 700 kW per engine, or air or space cooling not exceeding 50, 0. Square meters.(D) The system of flow in the pipe, pressure or vacuum pick up with the pressure of the flow in the pipes in all sizes except fluid as toxic or hazardous, according to the law. On the whole, the control of hazardous material, this means including a general cooling compounds.(E) energy management of all sizes(F) fire protection and fire fighting systems of all sizes.(3) the production control(A) mechanical size combined do not exceed 2, 0 kW per machine.(B) steam or steam generator. Pressure vessel or furnace industry pressure does not exceed 4, 0 k Pascal or pressure vessel volume not exceeding 30 cubic meters per tank or steam production rate or something else does not exceed 30, 0 kg per hour.(C) complications, air dryer or a refrigeration cooling does not exceed 1, 500 kW per machine.(D) The system of flow in the pipe, pressure or vacuum pick up with the pressure of the flow in the pipe not more than 0, 3 kilo Pascal unless fluid is toxic or hazardous substances according to the law. On the whole, the control of hazardous material, this means including a general cooling compounds.(E) fire protection systems and fire protection in all sizes.(4) consideration of all types of audit work and in all sizes.(5) further work to use.(A) mechanical size combined do not exceed 5, 0 kW.(B) steam or steam generator. Pressure vessel or industrial furnace pressure not exceeding 5, 0 k Pascal or steam production rate or something else does not exceed 100, 0 kg per hour per engine, or a combination of no more than 300, 0 kg per hour per system.(C) air or compressed gas boiler boiler pressure not exceeding size 5, 0 k, and has a volume of not more than Pascal 50 cubic meters.(D) Air cooling air or deficiencies in all sizes(E) The system of flow in the pipe, pressure or vacuum pick up with the pressure of the flow in the pipes in all sizes except fluid as toxic or hazardous, according to the law. On the whole, the control of hazardous material, this means including a general cooling compounds.(F) fire protection and fire fighting systems of all sizes.
การแปล กรุณารอสักครู่..