Rules of the Ministry ofDefine facilities in the building.For disabled or disability and old people.2548 (2005)----------------------- Live, on-demand power, in section 5 (3) of the Act and section 2522 (1979) building control 8 (1) (4) (5) (6) (7) (8) and (9) of the Act govern amendments 2522 (1979) building, by the building control Act (issue 3) 2543 (2000) as the Act contains certain provisions on limiting the rights and freedoms of the person which section 29 to 31 35 48 scale scale scale scale scale 49 and 50 of the Constitution of the Kingdom of Thai law, performed by residents in early April. The law's provisions provide an na Minister of Interior by the recommendations of the Board of control to rule out building. In the following ways:Article 1 of the rules in force when the sixty days since the date of publication in the Government Gazette, etc.Article 2 in this Ministry rules."The facilities for disabled or old people and disabled" means that portion of a building that is created is device and the components of the building or located inside and outside the building to facilitate the use of the building for persons with disabilities or disability and old people."Elevator" means a device used to bring people up and down between floors of a building at different levels, but not the escalator or scrolling."Different surface exposure" means the surface with texture and color that is different from the surface and the color in the vicinity where people can experience vision disabilities."Net width" means the width measured from one point to another without anything obstructing.The building of 3 categories and the following characteristics: To provide facilities for disabled or old people and disability as defined in the rules for this Ministry. The area is open to the general public.(1) hospital. Hospital Public health service, Center for sanitary station. The building of the public State enterprises Government Organization established by law. Institute of Museum and library of the State, such as mass transit railway station airport. Railway station bus station The pier has a specific area of the building is open to the general public as well as more than 300 square meters.(2) the Office of the Grand marasop hotel, shopping centers, Sports Hall. Different types of department stores that have a specific area of the building is open to the general public over 2, 0. Square meters.Chapter 1Facilities labels-----------------------Article 4 3 of the building must be provided with labels, facilities for disabled people or people with disabilities, and appropriate for the contents with details as follows:(1) the blind bullets(2) sign shows the way to a facility for disabled people or people with a disability and old.(3) a symbol or letter shows the type of facilities for disabled or old people and disabled.5 the blind bullets Markers to facilities for disabled or disability and old people and a symbol or letter shows the type of facilities for disabled or old people with disabilities and meet the 4 white blue badge or background with a blue background and white label.Article 6 label showing facilities for disabled or old people, have a disability and need to have a clear. Easy to see. Stuck in a position that does not cause confusion, and to provide extra lighting light both day and night.Chapter 2Ramp and elevator-----------------------Article 7 hakradap 3 by building ground floor level inside the building or inside the building with outdoor or exterior corridor floor level there is a different level exceeding 20 mm, with different space elevator or ramp between the levels. But if there is a difference. do not exceed 20 mm finishing surface must be the same level of personal views does not exceed 45 degrees.Article 8 the ramp, has the following characteristics:(1) the surface of the ramp must be non-slip.(2) the surface of continuous point between smooth surfaces must be smooth, with no ramp.(3) the net width of not less than 900 mm in the case of the ramp with the length of each session together since 6, 0 mm up to. NET width must be no less than 1, 500 mm.(4) there is an empty space in front of the ramp length cannot be less than 1, 500 mm.(5) the ramp must have a slope not exceeding. 1: 12 and the interval length cannot exceed 6, 0 mm, in the case that the LAT 0, 6 mm beyond the need to provide Shan long stay of not less than 1, 500 mm between each interval of the ramp.(6) there are no side ramp wall, lifting the edges up from the surface of the ramp is not less than 50 mm, and c. West.(7) the ramp with a length ranging from 2 up to 500 mm, Must have handrails on both sides, with the following characteristics:(A) is made with smooth material. With strong stability Harmless in the match and did not slide.(B) a round with a diameter of not less than 30 mm but not exceeding 40 mm.(C) high from floor not less than 800 mm but not exceeding 900 mm.(D) the side rails are wall-mounted, with the distance from the wall, not less than 50 mm is the height from the base point of not less than 120 mm and a wall surrounding a smooth wall handrails.(E) Handrails must be continuous and long sections that adhere to the wall must not hinder or prevent the use of people with disabilities through vision.(F) The ends of the Rails, so filing from the beginning and the end of the ramp is not less than 300.Mm(8) there are signs showing the direction, position, or a number of persons with disabilities to buildings and the old man sees the can know what it means. Located on the way up and down the ramp that connects between the floors of the building.(9) the symbols on the ramp area installed for persons with disabilities provided to disabled people or people with a disability and old.9 Article 3 according to a building that has two or more layers layer number must be provided with an elevator or ramp that is accessible or disability and old people use between floors of the building.Lifts for persons with disabilities or with disabilities and old people used to be able to get up and down, all over the floor. The elevator control system is disabled or has a disability, and old ones can be controlled manually. Work safely and be in areas where disabled people or people with a disability and the old can be used instead of.
การแปล กรุณารอสักครู่..